產品名稱:Half or full rack programmable DC power supply產品型號:Sorensen XG 850 WattSorensen XG 850 WattHalf or full rack programmable DC power supply for greater accuracy and efficiencyProduct OverviewThe Sorensen XG Series is an 850 Watt, 1U half-rack DC power supply. The XG Series is the

產品介紹

產品名稱:Half or full rack programmable DC power supply

產品型號:Sorensen XG 850 WattSorensen XG 850 Watt
Half or full rack programmable DC power supply for greater accuracy and efficiency


Product Overview 
The Sorensen XG Series is an 850 Watt, 1U half-rack DC power supply. The XG Series is the new standard for powerful, programmable DC power systems. Designed for test, production, laboratory, OEM and quality assurance applications, the XG Series provides a wealth of features to ensure accuracy and greater efficiency. It puts clean, reliable power at your disposal and delivers stable, variable output voltage and current for a broad range of development, test and system requirements.

Features And Benefits
Highest Power Density 
The Sorensen XG Series is an 850 Watt, 1U half-rack DC power supply. The XG Series is the new standard for powerful, programmable DC power systems. Designed for test, production, laboratory, OEM and quality assurance applications, the XG Series provides a wealth of features to ensure accuracy and greater efficiency. It puts clean, reliable power at your disposal and delivers stable, variable output voltage and current for a broad range of development, test and system requirements.

Comprehensive Digital and Analog Interface Options 
The XG Series comes standard with USB 2.0, RS-232, RS-485, isolated and non-isolated analog interfaces to provide a comprehensive set of options to connect to a PC or other network device. This design provides the convenience of being able to accommodate a wide range of installation configurations. Ethernet and GPIB interfaces are available as options.

Scalable, Multi-Unit Design
XG Series power supplies can be connected in parallel or series to produce greater current or voltage output for your applications. This scalability allows you to build rackmounted systems with the XG Series that exactly meet your existing requirements, while allowing for future expansion.

Multi-Channel Support
Up to 30 XGs Series can be connected easily via an RS-485 bus to provide the ultimate flexibility in remote programming. This eliminates the cost and complexity of requiring GPIB cards in each unit. Once connected, multiple power supplies can be controlled via a single LAN, USB 2.0, GPIB, RS-232 or RS-485 interface. This provides an efficient option to centrally manage each XG Series needed for your applications.

Straightforward Front Panel Controls 
The XG Series is equipped with a unique push-button encoder and function selector dial to provide a simple, uncluttered front panel. Both voltage and current can be set quickly and easily using these two controls. Front panel access can be locked out to ensure secure remote operation. This streamlined front panel layout results in fast, intuitive set-up and operation of the XG Series.

High Reliability 
To guarantee long-term trouble-free performance, the XG Series was designed with reliability in mind. Softswitching technology ensures higher mean time between failure (MTBF) by eliminating high voltage transients found in conventional hard-switching power supplies which can cause premature failure of power components. AMETEK engineers also rigorously tested the XG Series during the design phase using Highly Accelerated Life Testing (HALT). This rigorous test procedure combines powerful thermal and vibration technologies to stress a product beyond its rated specifications. HALT testing allows our engineers to uncover and correct design issues early in the development cycle. This care in design and comprehensive testing ensures the XG Series exceeds the reliability and quality standards of both AMETEK and our customers.

Five-Year Warranty 
The XG is backed by a comprehensive five-year warranty, the longest in the market. Our superior design and testing techniques result in highly reliable products that will provide you with years of trouble-free performance.

Specifications
Output Ratings
ModelOutput Voltage 1Output Current 2, 9Output Power 3
XG 6-1106 V110 A670 W
XG 8-1008 V100 A810 W
XG 12-7012 V70 A850 W
XG 20-4220 V42 A850 W
XG 33-2533 V25 A835 W
XG 40-2140 V21 A850 W
XG 60-1460 V14 A850 W
XG 80-10.580 V10.5 A850 W
XG 100-8.5100 V8.5 A860 W
XG 150-5.6150 V5.6 A850 W
XG 300-2.8300 V2.8 A850 W
XG 600-1.4600 V1.4 A850 W
Line Regulation
ModelVoltage (0.005% of rated 
output voltage +2 mV) 4
Current (0.01% of rated 
output current +1 mA) 5

XG 6-1102.3 mV13 mA
XG 8-1002.4 mV12 mA
XG 12-702.6 mV9 mA
XG 20-423.0 mV6.2 mA
XG 33-253.7 mV4.5 mA
XG 40-214 mV4.1 mA
XG 60-145 mV3.4 mA
XG 80-10.56 mV3.1 mA
XG 100-8.57 mV2.9 mA
XG 150-5.69.5 mV2.6 mA
XG 300-2.817 mV2.3 mA
XG 600-1.432 mV2.1 mA
Load Regulation
ModelVoltage (0.005% of rated 
output voltage + 2 mV) 6
Current (0.02% of rated 
output current +4 mA) 7

XG 6-1102.3 mV27 mA
XG 8-1002.4 mV25 mA
XG 12-702.6 mV19 mA
XG 20-423.0 mV13.4 mA
XG 33-253.7 mV10 mA
XG 40-214 mV9.2 mA
XG 60-145 mV7.8 mA
XG 80-10.56 mV7.1 mA
XG 100-8.57 mV6.7 mA
XG 150-5.69.5 mV6.1 mA
XG 300-2.817 mV5.6 mA
XG 600-1.432 mV5.3 mA
Output Ratings
ModelOutput Noise (rms, 300 kHz)Output Ripple 
(p-p, 20 MHz)
VoltageCurrent 8Voltage
XG 6-1108 mV200 mA50 mV
XG 8-1008 mV180 mA50 mV
XG 12-708 mV120 mA50 mV
XG 20-428 mV75 mA50 mV
XG 33-258 mV60 mA50 mV
XG 40-218 mV45 mA50 mV
XG 60-148 mV35 mA50 mV
XG 80-10.58 mV25 mA80 mV
XG 100-8.58 mV20 mA80 mV
XG 150-5.610 mV16 mA100 mV
XG 300-2.825 mV10 mA150 mV
XG 600-1.450 mV6 mA250 mV

1. Maximum output voltage is guaranteed to be ≤ 0.2% of the rated voltage at zero output setting, using the front panel or digital remote programming modes.
2. Maximum output current is guaranteed to be ≤ 0.4% of the rated current at zero output setting, using the front panel or digital remote programming modes, and when measured with rated load resistance.
3. Total output power is also based on AUX1 Output Voltage (5 V) and AUX1 Output Current (0.5 A) and AUX2 Output Voltage (15 V) and AUX2 Output Current (0.5 A).
4. From 85–132 Vac or 170–265 Vac, constant load.
5. From 85–132 Vac or 170–265 Vac, constant load.
6. From no load to full load, constant input voltage.
7. For load voltage change, equal to the unit voltage rating, constant input voltage.
8. For 6 V models the current ripple is measured at 2–6 V output voltage and full output current. For all other models, the current ripple is measured at 10–100% output voltage and full output current.
 

Note: All specifications are subject to change.

Output Ratings
ModelMaximum Recommended Remote Sense Line Drop Compensation per Line10Up-prog. Response Time, 0~Vmax 11Efficiency (100/200 VAC input) 12
XG 6-1101 V60 ms75/77%
XG 8-1001 V60 ms77/80%
XG 12-701 V60 ms79.5/82.5%
XG 20-421.5 V60 ms82/85%
XG 33-252 V60 ms83/86%
XG 40-212 V60 ms83/87%
XG 60-143 V60 ms83/87%
XG 80-10.55 V100 ms83/87%
XG 100-8.55 V100 ms83/87%
XG 150-5.65 V100 ms83/87%
XG 300-2.85 V150 ms83/87%
XG 600-1.45 V250 ms83/87%
Output Ratings
ModelDown-prog. Response Time: Full LoadDown-prog. Response Time: No LoadOver-Voltage Trip Point
XG 6-11050 ms300 ms0.5–7.5 V
XG 8-10050 ms400 ms0.5–10 V
XG 12-7050 ms500 ms1–15 V
XG 20-4250 ms600 ms1–24 V
XG 33-2550 ms700 ms2–39 V
XG 40-2150 ms800 ms2–44 V
XG 60-1450 ms900 ms3–66 V
XG 80-10.580 ms1000 ms3–95 V
XG 100-8.5100 ms1200 ms3–125 V
XG 150-5.6150 ms1800 ms3–180 V
XG 300-2.8150 ms2200 ms5–330 V
XG 600-1.4250 ms3500 ms5–660 V
Regulatory Approvals
Safety
 
CSA 22.2 No. 61010-1, 60950-1-07 and UL61010-1, UL60950-1-(2nd Ed).19  Marked with cCSAus, CE for EMC & low voltage directive
EMCComplies with EN61326-1 
Complies with EN55022, Class B, FCC Part 15B for conducted emissions 
Complies with EN55022, Class A, FCC Part 15A for radiated emissions 
Complies with EN61000-4 series of standards for immunity

9. When using remote sense, the total of the load voltage and the load line drops must not exceed the rated output of the power supply. For example, for an XG 6-110 in an application with 1 V of
load line loss (0.5 V/Line), the maximum available load voltage would be 6–1= 5 V. Note: The unit may operate at higher output voltages than this, but there is no guarantee that the power supply
will meet performance specifications. Ultimately, the upper limit of the output voltage will be determined by internal circuitry of the power supply (non-adjustable.)
10. With rated, resistive load.
11. At maximum output power.
12. Double insulation on primary to secondary isolation barriers. Basic insulation primary to protective earth ground.
 

Applies to all footnotes: Programming and Readback: RS-232, RS-485, USB built in. GPIB, Ethernet optional. Specifications are guaranteed from 1% to 100% of the rated output voltage, current, and power.
 

Note: All specifications are subject to change.

Environmental Specifications (Indoor use)
Operating Temperature Range32°F to 122°F, 100% load (0°C to 50°C)
Storage Temperature Range-4°F to 158°F (–20° C to 70°C)
Operating Humidity Range30–90% RH (no condensation)
Storage Humidity Range10–95% RH (no condensation)
Operating AltitudeUp to 6,500 feet (2,000 m)
Installation CategoryII (IEC 1010-1)
Pollution Degree2 (IEC 1010-1)
Output Performance Specifications
Temperature Coefficient100 PPM/° C from rated output voltage, after a 30-minute warm-up
Drift (8 hours)0.05% of rated output voltage & current over an 8 hour interval with constant line, load & temperature, after a 30-minute warm-up
Hold-up TimeTypical 20 ms at any rated input line.
Transient Response Time2Less than 1 ms for 6 V to 60 V models. Less than 2 ms for 80 V to 600 V models
Meter Accuracy0.5% ± 1 count
Aux Output 1+5V: +0.4V, – 0.5V at 0.4A +15V: +1.2V, – 1.4V at 0.4A
Isolation 41500Vac or 2121Vdc between mains terminals and accessible conductive parts / chassis ground. 
Output to chassis 18 500Vac.

1. Current: 0.51 A minimum guaranteed, 0.72 A typically available. Overcurrent protection (each output) is automatic, non-latching. When OCP is tripped the aux voltage folds back and will recover to nominal condition
when the over current condition is removed (typ. <0.2A). To protect external circuits attached to the aux outputs it is recommended that customers use an appropriately rated fuse in series with the aux outputs set point 10-100%
2. Time for the output voltage to recover within 0.5% at its rated output for a load change 10-90% of rated output current. Output set point 10-100%
3. For floating chassis ground applications, please contact application engineering for system design assistance.
4. Double insulation on primary to secondary isolation barriers. Basic insulation primary to protective earth ground.
Note: All specifications are subject to change.