聯絡我們:07-9738888
產品介紹

Sorensen HPD Series (已停產)

產品名稱:(0-300W) Programmable linear DC power supply產品型號:Sorensen HPD SeriesSorensen HPD Series (0-300W)Programmable linear DC power supply in a quarter rack packageProduct OverviewThe Sorensen HPD Series provides 300 watts in a quarter–rack wide chassis. It is ideal for OEM applicatio

產品介紹

產品名稱:(0-300W) Programmable linear DC power supply

產品型號:Sorensen HPD Series

Sorensen HPD Series (0-300W)
Programmable linear DC power supply in a quarter rack package

Product Overview 
The Sorensen HPD Series provides 300 watts in a quarter–rack wide chassis. It is ideal for OEM applications where wide adjustment of output voltage or current is required in a compact package, providing up to 300 watts of clean power. HPD is available in three models and is the smallest 300–watt programmable power supply available. 

HPD uses switch–mode technology combined with linear post regulation to provide performance comparable to an all–linear design. Excellent line and load regulation is matched by low noise and good transient response. HPD is available in singles and duals in a single package for benchtop use. It can be combined in mix and match rack combinations with the quarter–rack 60 watt XT or 500 watt XPD. For systems applications, multiple units can be rack mounted in one to four unit configurations for up to four independent 300–watt outputs.

Key Features

● Low noise and ripple
● Excellent line/load regulation
● Constant voltage or constant current operation with automatic crossover and mode indication
● Current limit
● Remote sense
● CE, CSA approvals

Specifications

Output Ratings¹
Model15-2030-1060-5
Output Voltage0-15 V0-30 V0-60 V
Output Current0-20 A0-10 A0-5 V
Output Power300 W300 W300 W
Line Regulation²
Model15-2030-1060-5
Voltage (0.01% of Vmax + 2 mV)3.5 mV5 mV8 mV
Current (0.05% of Imax + 2 mA)12 mA7 mA4.5 mA
Load Regulation³
Model15-2030-1060-5
Voltage (0.01% of Vmax + 2 mV)3.5 mV5 mV8 mV
Current (0.05% of Imax + 2 mA)12 mA7 mA4.5 mA
Meter Accuracy
Model15-2030-1060-5
Voltage (1% of Vmax + 1 count)250 mV400 mV700 mV
Current (1% of Imax + 1 count)300 mA200 mA60 mA
Output Noise & Ripple
Model ( Rear Panel )15-2030-1060-5
Voltage rms5 mV5 mV5 mV
Voltage (p-p) (0-20 MHz)75 mV75 mV100 mV
Drift (8 hours): 4
Model15-2030-1060-5
Voltage (0.02% of Vmax)3 mV6 mV12 mV
Current (0.08% of Imax)16 mA8 mA4 mA
Temperature coefficient: 5
Model15-2030-1060-5
Voltage (0.015% of Vmax/° C)2.25 mV4.5 mV9 mV
Current (0.02% of Imax/° C)4 mA2 mA1 mA
Interface Specifications: 1,6
Model15-2030-1060-5
Program Resolution (16-bit)
Voltage0.25 mV0.5 mV1.01 mV
Current0.34 mA0.17 mA0.08 mA
OVP0.25 mV0.5 mV1.01 mV
Program Accuracy
Voltage (0.2% + 10 mV)60 mV 
(+/- 0.1%)
70 mV 
(+/- 0.1%)
90 mV 
(+/- 0.12%)
Current (0.3% + 10 mA)75 mA 
(+/- 0.12%)
50 mA 
(+/- 0.12%)
25 mA 
(+/- 0.1%)
OVP (0.5%) + 100 mV)1500 mV3000 mV6000 mV
Readback Resolution (16-bit)
Voltage0.25 mV0.5 mV1.01 mV
Current0.34 mA0.17 mV0.08 mA
Readback Accuracy
Voltage (0.2% + 20 mV)45 mV 
(+/- 0.3%)
90 mV 
(+/- 0.3%)
175 mV 
(+/- 0.3%)
Current (0.3% + 20 mA)75 mA 
(+/- 0.12%)
40 mV 
(+/- 0.12%)
25 mA 
(+/- 0.1%)
.

1. Specifications indicate typical performance at 25° C +/- 5° C, nominal line input of 120 VAC.
2. For input voltage variation over the AC input voltage range, with constant rated load.
3. For 0-100% load variation, with constant nominal line voltage.
4. Maximum drift over 8 hours with constant line, load and temperature, after 60 minutes warm-up.
5. Change in output per ° C change in ambient temperature, with constant line and load.
6. Apply accuracy specifications according to the following voltage program accuracy example:
    Set a model 15-20 power supply to 10 volts. The expected result will be within the range of
    10 volts +/- 60 mV +/- 0.1% of the set voltage of 10 volts.

General Specifications
Operational AC input voltageSingle unit: 104-127 VAC at 6 Arms; Dual unit: 104-127 VAC at 12 Arms, 47-63 Hz
Switching Frequency100 kHz (nominal)
Voltage Mode Transient Response Time<500 µs recovery to 50 mV band for ±50% load change in the range of 25% to 100% of the rated load
Operating Ambient Temperature0 to 30° C for full rated output. Above 30°C, derate output linearly to zero at 70° C
Storage Temperature Range-55° C to 85° C
Humidity Range0 to 80% RH, non-condensing
Front Panel Voltage and Current Control10-turn voltage and 1-turn current potentiometers (10-turn current optional)
Front Panel Voltage Control Resolution0.02% of maximum voltage
AC Input Connector TypeIEC 320 connector
Weight (one unit)Approximately 7.7 lb (3.5 kg)
Dimensions (H x W x D)5.2 x 4.2 x 11.7” (132 x 109.2 x 297 mm)
Analog Programming
Remote On/Off and Interlock2-25 VDC high. <0.8 VDC low. User-selectable.
Remote analog Programming Option0-10 VDC for 0-100% of rated voltage or current ±1.0%, 0-10 kΩ for 0-100% of rated voltage or current ±1.0%
Remote Monitoring0-10 VDC for 0-100% or rated voltage or current ±1.0%
Over Voltage Protection Trip Range3 V to full output ±10%
Tracking Accuracy±1% for series operation
Regulatory Approvals
CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; CSA C/US certified to UL61010-1B and CSA C22.2 No 1010.1; Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001, Class A.
Specifications subject to change without notice.


產品型錄下載