聯絡我們:07-9738888
產品介紹

Sorensen XPD Series (已停產)

產品名稱:(0-500W) One Quarter Rack Programmable Benchtop DC Power Supplies產品型號:Sorensen XPD SeriesSorensen XPD Series (0-500W)One Quarter Rack Programmable Benchtop DC Power SuppliesProduct OverviewWith up to 540 watts of programmable DC power in a quarter-rack wide chassis, the Sorensen

產品介紹

產品名稱:(0-500W) One Quarter Rack Programmable Benchtop DC Power Supplies

產品型號:Sorensen XPD Series

Sorensen XPD Series (0-500W)
One Quarter Rack Programmable Benchtop DC Power Supplies

Product Overview 
With up to 540 watts of programmable DC power in a quarter-rack wide chassis, the Sorensen XPD is the highest power density product available in its power range. Choose from five models for benchtop and OEM applications, where a wide adjustment of output voltage or current is required in a compact package. 

The Sorensen XPD utilizes state–of–the–art zero voltage or "soft" switching technology to virtually eliminate switching transients for high efficiency, low noise and high reliability. It is also power factor corrected for low current draw and reduced generation of input current harmonics. For systems applications, XPD can be rack mounted in multiple-unit configurations of up to four independent 500 watt outputs. For example, XPD can be combined with other Xantrex programmable DC power supplies such as the quarter­rack 300 watt HPD and the 60 watt XT.

Key Features

● Analog programming
● Universal input
● Zero voltage “soft switching”
● Power factor correction (PFC)
● Front and rear connectors
● Ten-turn front panel knobs
● Remote sense with 5V line loss compensation
● LabVIEW® and LabWindows® drivers

Specifications

Output : Voltage and Current
ModelOutput 
Voltage (2)
Output 
Current (3)
Output 
Power
XPD 7.5-670-7.5 V0-67 A502.5 W
XPD 18-300-18 V0-30 A540 W
XPD 33-160-33 V0-16 A528 W
XPD 60-90-60 V0-9 A540 W
XPD 120-4.50-120 V0-4.5 A540 W
Line (4) and Load (5) Regulation
ModelLine Regulation VoltageLine Regulation CurrentLoad Regulation VoltageLoad Regulation Voltage
XPD 7.5-672 mV2 mA2 mV4 mA
XPD 18-302 mV2 mA4 mV4 mA
XPD 33-163 mV2 mA4 mV4 mA
XPD 60-93 mV2 mA4 mV4 mA
XPD 120-4.53 mV2 mA5 mV4 mA
Meter Accuracy
ModelVoltage 
(1% of Vmax + 1 count)
Current 
(1% of Imax + 1 count)
XPD 7.5-670.2 V0.8 A
XPD 18-300.3 V0.4 A
XPD 33-160.5 V0.3 A
XPD 60-90.7 V0.2 A
XPD 120-4.52.2 V0.2 A
Output : Noise and Ripple
ModelOutput 
Noise (90-20 MHz)
Output Ripple
Voltage
Output Ripple
Current (6)
XPD 7.5-6750 mV5 mV250 mA
XPD 18-3050 mV5 mV250 mA
XPD 33-1675 mV7.5 mV150 mA
XPD 60-9125 mV10 mV150 mA
XPD 120-4.5180 mV20 mV75 mA
Drift
ModelDrift (60 minutes) (7)Drift (8 hours) (8)
Voltage (0.15% of Vmax)Current 
(0.3% of Imax)
Voltage (0.03% of Vmax)Current (0.05% of Imax)
XPD 7.5-6711.3 mV201 mA2.3 mV34 mA
XPD 18-3027 mV90 mA5.4 mV15 mA
XPD 33-1649.5 mV48 mA9.9 mV8 mA
XPD 60-990 mV27 mA18 mV4.5 mA
XPD 120-4.5180 mV13.5 mA36 mV2.3 mA
Temperature Coefficient (9)
ModelVoltage 
(0.015% of Vmax/°C)
Current 
(0.02% of Imax/°C)
XPD 7.5-671.2 mV13.4 mA
XPD 18-302.7 mV6 mA
XPD 33-165 mV3.2 mA
XPD 60-99 mV1.8 mA
XPD 120-4.518 mV0.9 mA
OVP Adjustment Range
Model(5% to 110% of Vmax)Efficiency (10)
XPD 7.5-670.4-8.3 V81%
XPD 18-300.9-19.8 V83%
XPD 33-161.7-36.3 V85%
XPD 60-93-66 V85%
XPD 120-4.56-132 V84%
XPD 500 including internal interface Specifications with RS-232 or GPIB Interface Installed (11)
Program Accuracy
ModelVoltage (mV)Current (mA)OVP (mV)
XPD 7.5-6710 (±0.12%) 75250 (±0.1%)80
XPD 18-30(±0.12%) 75140 (±0.1%)200
XPD 33-16(±0.12%) 150115 (±0.15%)330
XPD 60-9(±0.3%) 18080 (±0.15%)600
XPD 120-4.5(±0.25%)80 (±0.1%)1200
Readback Accuracy
ModelVoltage (mV)Current (mA)
XPD 7.5-6730 (±0.12%)250 (±0.1%)
XPD 18-3075 (±0.12%)140 (±0.1%)
XPD 33-1675 (±0.2%)115 (±0.15%)
XPD 60-9150 (±0.3%)80 (±0.15%)
XPD 120-4.5180 (±0.25%)80 (±0.1%)
Input
Operational AC Input Voltage85-264 Vac, 47-63 Hz; power factor corrected. Derate maximum output power to 450 W for AC input less than 95 V.
Maximum Input Current7 A maximum at 100 Vac, 6 A maximum at 120 Vac, 3 A maximum at 220 Vac
General Specifications
Power Factor0.98 minimum for full load at nominal voltage
Input Harmonic DistortionCurrent harmonics meet IEC 1000-3-2
Switching Frequency125 kHz (250 kHz output ripple)
Time Delay3 sec maximum, from power on to output stable
Voltage Mode Transient Response Time1 ms for output voltage to recover within 0.5% of its previous level after a step change in load current of up to 50% of rated output
Maximum Voltage Differential±300 Vdc from output to safety ground
Remote On/Off and Interlock5-15 V signal or TTL-compatible input, selectable logic. TTL input impedance: 2 k (in series with one diode drop)
Remote Analog Programming
(Full Scale Input)
Voltage and current programming inputs (source must be floating): 0-10 V voltage sources. Input impedance (V and I): 20 k
Remote Programming &
Monitoring Accuracy
1% of full scale output for the default range
Front Panel Voltage and Current Control10-turn voltage and current potentiometers
Front Panel Voltage Control Resolution0.02% of maximum voltage
AC Input Connector TypeIEC 320 connector, appropriate power cord provided for destination country
Main Output ConnectorFront panel: five-way binding posts. Maximum current limit 30 A; Rear Panel: 7.5-18 V models: Bus bars;
33-120 V models: wire clamp connectors.
ApprovalsCE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; CSA C/US certified to UL3111-1 and CSA C22.2 No 1010.1;
Meets USA EMC standard: FCC, part 15B, Class A; Meets Canadian EMC standard: ICES-001, Class A.
Environmental
Operating Temperature0 to 50°C
Storage Temperature-40°C to 85°C
Humidity RangeUp to 95% RH, non-condensing
Physical
DimensionsWidth: 4.2” (109.2 mm)
Height: 5.2” (134.7 mm)
Depth: 13” (330 mm)
Weight9.0 lb (4.1 kg)
Protection Features
Over voltage protection per output
Switchable remote or local sense
Specifications subject to change without notice.
1. All electrical specifications are represented at the full operating temperature range for all models, unless otherwise stated.
2. Minimum output voltage is < 0.15% of rated voltage at zero output setting.
3. Minimum output current is < 0.2% of rated current at zero setting when measured with rated load resistance. Front output current limited to 30 A maximum.
4. For input voltage variation over the AC input voltage range, with constant rated load.
5. For 0-100% load variation, with constant nominal line voltage.
6. Current mode noise is measured from 10% to 100% of rated output voltage, full current.
7. Maximum drift over 60 minutes with constant line, load, and temperature, after power up.
8. Maximum drift over 8 hours with constant line, load, and temperature, after 60 minute warm-up.
9. Change in output per °C change in ambient temperature, with constant line and load.
10. Typical efficiency at 120 V and full output power.
11. Interface specifications at 25°C ± 5°C, nominal line input of 120 Vac. Apply accuracy specifications according to the following voltage program accuracy example: Set a model 18-30 power supply to 10 V. The expected result will be within the range of 10 V ± 75 mV ± 0.12% of the set voltage of 10 V.


產品型錄下載