聯絡我們:07-9738888
產品介紹

Sorensen XHR Series (已停產)

產品名稱:(1000W) programmable DC power supply產品型號:Sorensen XHR SeriesSorensen XHR Series (1000W)Programmable DC power supply in a half rack size, ideal for applications where high power and wide adjustment of output voltage or current is required, and a compact half-rack configuration is advan

產品介紹

產品名稱:(1000W) programmable DC power supply

產品型號:Sorensen XHR Series

Sorensen XHR Series (1000W)
Programmable DC power supply in a half rack size, ideal for applications where high power and wide adjustment of output voltage or current is required, and a compact half-rack configuration is advantageous.

Product Overview 
XHR provides 1000 watts of programmable DC power in a compact half-rack package. It is available in eighteen 1 kW models. Its unique features and size make XHR ideal for OEM applications where high power and wide adjustment of output voltage or current is required, and a compact half-rack configuration is advantageous. 

It is stackable with a small foot print, front panel binding post connectors and a low current requirement that allows it to be plugged into a standard 120 VAC, 15 A circuit. State-of-the-art zero voltage or "soft" switching technology virtually eliminates switching transients for high efficiency, low noise and high reliability. XHR is also power-factor-corrected for low current draw (only 11 A at 120 VAC for 1000 watts) and reduced generation of input current harmonics. 

The half-rack XHR is ideal as a "companion" for another half-rack instrument in a test system equipment console, eliminating the need for a blank panel while preserving vertical rack space. With a choice of rear and/or front panel connectors, XHR offers added system flexibility.

Key Features

● 85-250 VAC universal input
● Standby mode
● Constant voltage or constant current operation with automatic crossover and mode indication
● Analog programming
● LabView® and LabWindows® drivers
● CE, CSA, UL approvals

Specifications

Common
Switching Frequency7.5 V to 300 V models: nominal 125 kHz (250 kHz output ripple); 600 V model: nominal 62.5 kHz (125 kHz output ripple)
Time Delay4 sec maximum from power on until output stable
Voltage Mode Transient Response Time1 ms for output voltage to recover within 0.5% of its previous level after a step change in load current of up to 50% of rated output
Maximum Voltage Differential±600 Vdc from output to safety ground
Remote Start/Stop and Interlock2.5-15 V signal or TTL-compatible input, selectable logic
Remote Analog ProgrammingVoltage and current programming inputs (source must be isolated): 0-5 k, 0-10 k resistances; 0-5 V (default), 0-10 V voltage sources
Remote Analog MonitoringVoltage and current monitor outputs 0-5 V (default), 0-10 V ranges for 0-100% of output
Remote Programming &
Monitoring Accuracy
1% zero to full scale output for the default range
Front Panel Voltage and Current Control10-turn voltage and current potentiometers
Front Panel Voltage Control Resolution0.02% of maximum voltage
Main Output Connector7.5 to 40 V models: nickel-plated copper bus bars;
60 to 600 V models: 4-terminal wire clamp connector for DC output and local sense
Protection FeaturesOver-voltage protection and Over-temperature protection
ApprovalsCE-marked units meet: EN61010-1, EN61000-6-2 
and EN61000-6-4;
CSA C/US certified to UL61010-1B and CSA C22.2 No 1010.1;
Meets USA EMC standard: FCC, part 15B, Class A;
Meets Canadian EMC standard: ICES-001, Class A.
Environmental
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 85°C
Humidity RangeUp to 80% RH, non-condensing
Physical
DimensionsWidth: 8.5” (216 mm)
Height: 3.4” (86.4 mm)
Depth: 18.6” (472.2 mm)
WeightApproximately 14 lbs. ( 6.4 kg )
Input
Voltage Ranges85-250 VAC, 47-63 Hz, power factor corrected. Derate maximum output power to 900 W for AC input less than 95 V
Power Factor99 minimum for full load and 120 Vac input
Current13 A maximum at 100 Vac;
11 A maximum at 120 Vac;
6 A maximum at 220 Vac
AC Input Connector TypeIEC 320 connector
Output
ModelOutput VoltageOutput CurrentOutput Power
XHR 7.5-1300-7.5 V0-130 C975 W
XHR 20-500-20 V0-50 C1000 W
XHR 33-330-33 V0-33 C1089 W
XHR 40-250-40 V0-25 C1000 W
XHR 60-180-60 V0-18 C1080 W
XHR 100-100-100 V0-10 C1000 W
XHR 150-70-150 V0-7 C1050 W
XHR 300-3.50-300 V0-3.5 C1050 W
XHR 600-1.70-600 V0-1.7 C1050 W
Output : At the front panel posts
ModelOutput Ratings
Voltage (VDC)Current (ADC)
XHR 7.5-1300-7.50-130
XHR 20-500-200-50
XHR 33-330-330-33
XHR 40-250-400-25
XHR 60-180-600-18
XHR 100-100-1000-10
XHR 150-70-1500-7
XHR 300-3.50-3000-3.5
XHR 600-1.70-6000-1.7
Output
ModelLine Regulation (2)Load Regulation (3)
VoltageCurrentVoltageCurrent
XHR 7.5-1303 mV14 mA3 mV66 mA
XHR 20-504 mV6 mA4 mV26 mA
XHR 33-335 mV4.3 mA5 mV18 mA
XHR 40-258 mV3.5 mA6 mV14 mA
XHR 60-188 mV2.8 mA8 mV10 mA
XHR 100-1012 mV2 mA12 mV6 mA
XHR 150-717 mV1.7 mA17 mV4.5 mA
XHR 300-3.532 mV1.3 mA32 mV3 mA
XHR 600-1.762 mV1.2 mA62 mV2 mA
Output
ModelMeter AccuracyOutput Noise
(0-20 MHz)
Voltage (p-p)
Output Ripple
(rms)
Voltage
Voltage
(0.5% to 1% of Vmax 
+ 1 count)
Current
(0.5% of Imax 
+ 1 count)
XHR 7.5-1300.09 V1.4 A70 mV10 mV
XHR 20-500.3 V0.6 A70 mV10 mV
XHR 33-330.43 V0.43 A75 mV7.5 mV
XHR 40-250.5 V0.35 A75 mV7.5 mV
XHR 60-180.7 V0.19 A75 mV10 mV
XHR 100-101.1 V0.11 A100 mV10 mV
XHR 150-71.6 V0.08 A150 mV20 mV
XHR 300-3.54 V0.05 A250 mV30 mV
XHR 600-1.77 V0.03 A500 mV120 mV
Output
ModelLoad Regulation (3)Meter Accuracy
VoltageCurrentVoltage
(0.5% to 1% of Vmax 
+ 1 count)
Current
(0.5% of Imax 
+ 1 count)
XHR 7.5-1303 mV66 mA0.09 V1.4 A
XHR 20-504 mV26 mA0.3 V0.6 A
XHR 33-335 mV18 mA0.43 V0.43 A
XHR 40-256 mV14 mA0.5 V0.35 A
XHR 60-188 mV10 mA0.7 V0.19 A
XHR 100-1012 mV6 mA1.1 V0.11 A
XHR 150-717 mV4.5 mA1.6 V0.08 A
XHR 300-3.532 mV3 mA4 V0.05 A
XHR 600-1.762 mV2 mA7 V0.03 A
Output
ModelOutput Noise
(0-20 MHz)
Voltage (p-p)
Output Ripple
(rms)
Voltage
Drift (8 hours) (4)
Voltage
(0.05% of Vmax)
Current
(0.1% of Imax)
XHR 7.5-13070 mV10 mV3.75 mV130 mA
XHR 20-5070 mV10 mV10 mV50 mA
XHR 33-3375 mV7.5 mV16.5 mV33 mA
XHR 40-2575 mV7.5 mV20 mV25 mA
XHR 60-1875 mV10 mV20 mV18 mA
XHR 100-10100 mV10 mV50 mV10 mA
XHR 150-7150 mV20 mV75 mV7 mA
XHR 300-3.5250 mV30 mV150 mV3.5 mA
XHR 600-1.7500 mV120 mV300 mV1.7 mA
Output
ModelTemperature Coefficient (5)Maximum Remote
Sense
Line Drop Compensation 6
OVP Adjustment
Range
(5%to 110% of Vmax)
Efficiency (7)
Voltage
(0.02% of Vmax/°C)
Current
(0.03% of Imax/°C)
XHR 7.5-1301.5 mV39 mA3 V / line0.375-8.25 V81%
XHR 20-504 mV15 mA5 V / line1-22 V83%
XHR 33-336.6 mV9.9 mA5 V / line1.65-36.3 V83%
XHR 40-258 mV7.5 mA5 V / line2-44 V83%
XHR 60-1812 mV5.4 mA5 V / line3-66 V84%
XHR 100-1020 mV3 mA5 V / line5-110 V84%
XHR 150-730 mV2.1 mA5 V / line7.5-165 V85%
XHR 300-3.560 mV1.1 mA5 V / line15-330 V85%
XHR 600-1.7120 mV0.48 mA5 V / line30-660 V85%
Specifications subject to change without notice.
1. Specifications indicate typical performance at 25°C ± 5°C, nominal line input of 120 Vac.
3. For 0-100% load variation, with constant nominal line voltage. Measured at the rear panel output connector unless stated otherwise.
4. Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up.
5. Change in output per °C change in ambient temperature, with constant line and load.
6. Line drop is subtracted from total voltage available at supply output.
7. Typical efficiency at 115 Vac input and rated output power.
8. Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-50 power supply to 10 V. The expected result will be within the range of 10 V ± 75 mV ± 0.12% of the set voltage 
of 10 V.