Sorensen XG 1700 Watt

產品名稱:(1700W) 1U programmable DC power supply產品型號:Sorensen XG 1700 WattSorensen XG 1700 Watt1700 Watt, 1U programmable DC power supply with constant voltage and constant current modesProduct OverviewThe XG 1500 is an industry leading programmable DC power supply designed for test, pro

產品介紹

產品名稱:(1700W) 1U programmable DC power supply

產品型號:Sorensen XG 1700 WattSorensen XG 1700 Watt
1700 Watt, 1U programmable DC power supply with constant voltage and constant current modes

Product Overview 
The XG 1500 is an industry leading programmable DC power supply designed for test, production, laboratory, OEM and quality assurance applications. The XG 1500 is a 1500 Watt, 1U programmable power supply with constant voltage and constant current modes, automatic cross-over and numerous features enabling cost effective, easy integration.

Features And Benefits
Easy Integration
XG 1500 has many control and indication signals such as shutdown, constant voltage (CV) vs. constant current (CC) mode indication, OVP, OCP, OTP, and so on. In addition, the logical-high or -low is free selectable. Thus enabling the XG 1500 to replace existing power supplies with little or no system engineering required.

Free selectable analog control range
Most DC power supplies provide a 0 to 5 or 0 to 10 V analog control range to control the DC output from zero to full DC output range. With the XG 1500, the analog control range is free selectable starting at 0V to an upper range between 2V and 10V. In other words, the analog programming interface range is freely adjustable.

Auxiliary DC output channels with control
In many ATE systems one or more low power, fixed voltage supplies are needed to provide electrical power for any periphery within the ATE cabinet. For this purpose, the XG 1500 provides two standard auxiliary DC output channels. Both auxiliary power channels are controllable directly from the front-panel or through SCPI commands. With these channels, it is possible to drive output-disconnect or polarity-reversal relays, without needing a complicated computer controlled relay board.

DC-waveforms through internal sequencing
To allow for extremely fast programming, sequences can be programmed into and stored in memory using standard SCPI commands through USB, RS-232/485, LXI or GPIB.

Variable Fan Speed Control
The XG 1500’s innovative approach to fan speed is determined by internal heat sink temperature. This allows the fans to adjust to a constant optimal speed when the output of the supply is being pulsed. This also reduces noise and increases fan life.

Power Saving Standby Mode
When the XG 1500 has been in an idle state, the supply can go into “sleep mode”, much like a computer monitor. This will allow the user to save energy and minimize lab noise. Since an XG 1500 left in sleep mode is still “on” the user will have quicker access to an enabled output.

Product Overview 
The XG 1700 is an industry leading programmable DC power supply designed for test, production, laboratory, OEM and quality assurance applications. The XG 1700 is a 1700 Watt, 1U programmable power supply with constant voltage and constant current modes, automatic cross-over and numerous features enabling cost effective, easy integration.

Features And Benefits
Easy Integration
XG 1700 has many control and indication signals such as shutdown, constant voltage (CV) vs. constant current (CC) mode indication, OVP, OCP, OTP, and so on. In addition, the logical-high or -low is free selectable. Thus enabling the XG 1700 to replace existing power supplies with little or no system engineering required.

Free Selectable Analog Control Range
Most DC power supplies provide a 0 to 5 or 0 to 10 V analog control range to control the DC output from zero to full DC output range. With the XG 1700, the analog control range is free selectable starting at 0V to an upper range between 2V and 10V. In other words, the analog programming interface range is freely adjustable.

Auxiliary DC Output Channels with Control
In many ATE systems one or more low power, fixed voltage supplies are needed to provide electrical power for any periphery within the ATE cabinet. For this purpose, the XG 1700 provides two standard auxiliary DC output channels. Both auxiliary power channels are controllable directly from the front-panel or through SCPI commands. With these channels, it is possible to drive outputdisconnect or polarity-reversal relays, without needing a complicated computer controlled relay board.

DC-Waveforms Through Internal Sequencing
To allow for extremely fast programming, sequences can be programmed into and stored in memory using standard SCPI commands through USB, RS-232/485, LXI or GPIB.

Variable Fan Speed COntrol
The XG 1700’s innovative approach to fan speed is determined by internal heat sink temperature. This allows the fans to adjust to a constant optimal speed when the output of the supply is being pulsed. This also reduces noise and increases fan life.

Power Saving Standby Mode
When the XG 1700 has been in an idle state, the supply can go into “sleep mode”, much like a computer monitor. This will allow the user to save energy and minimize lab noise. Since an XG 1700 left in sleep mode is still “on” the user will have quicker access to an enabled output.

Output Auto Start Mode (Auto Restart)
The Auto Start mode establishes the state of the output of the power supply after recovery from a complete power cycle (all front panel LEDs are not illuminated), or after recovery from a PC failure or reboot. If Auto Start mode is set to On, the power supply output will return to its previous value. Also, after the loss of any remote digital control, the XG unit will remain active in its last programmed setting and will not disrupt any test process.

Auxiliary Auto Start Mode
The Auxiliary Auto Start mode determines the state of the auxiliary output after a complete power cycle (all front panel LEDS are not illuminated). With Auxiliary Auto Start mode turned to On, the auxiliary output will be activated after the power supply is powered up again.

Foldback Mode
Foldback mode is used to disable the output when a transition is made between the operating modes. The power supply will turn off/disable the output and lock in foldback mode after a specified delay if the power supply transitions into CV mode or into CC mode, depending on the foldback mode settings. This feature is particularly useful for protecting current or voltage sensitive loads. Foldback can be set to trigger a switch when transitioning from CV to CC mode or from CC to CV mode.

Specifications

Output Ratings
ModelOutput Voltage¹Output Current²Output Power³
XG 6-2206 V220 A1330 W
XG 8-2008 V200 A1610 W
XG 12-14012 V140 A1690 W
XG 20-8420 V84 A1690 W
XG 33-5033 V50 A1690 W
XG 40-4240 V42 A1690 W
XG 60-2860 V28 A1690 W
XG 80-2180 V21 A1690 W
XG 100-17100 V17A1710 W
XG 150-11.2150 V11.2 A1690 W
XG 300-5.6300 V5.6 A1690 W
XG 600-2.8600 V2.8 A1690 W
Line Regulation
ModelVoltage (0.005% of rated 
output voltage +2 mV)4
Current (0.01% of rated 
output current +2 mA)5

XG 6-2202.3 mV24 mA
XG 8-2002.4 mV22 mA
XG 12-1402.6 mV16 mA
XG 20-843.0 mV10.4 mA
XG 33-503.7 mV7 mA
XG 40-424 mV6.2 mA
XG 60-285 mV4.8 mA
XG 80-216 mV4.1 mA
XG 100-177 mV3.7 mA
XG 150-11.29.5 mV3.12 mA
XG 300-5.617 mV2.56 mA
XG 600-2.832 mV2.28 mA
Load Regulation
ModelVoltage (0.005% of rated 
output voltage + 2 mV)6
Current (0.02% of rated 
output current +5 mA)7

XG 6-2202.3 mV49 mA
XG 8-2002.4 mV45 mA
XG 12-1402.6 mV33 mA
XG 20-843.0 mV22 mA
XG 33-503.7 mV15 mA
XG 40-424 mV13 mA
XG 60-285 mV1.06 mA
XG 80-216 mV9.21 mA
XG 100-177 mV8.4 mA
XG 150-11.29.5 mV7.2 mA
XG 300-5.617 mV6.1 mA
XG 600-2.832 mV5.6 mA
Output Ratings
ModelOutput Noise (rms, 300 kHz)Output Ripple 
(p-p, 20 MHz)
VoltageCurrent8Voltage
XG 6-2208 mV400 mA50 mV
XG 8-2008 mV340 mA50 mV
XG 12-1408 mV240 mA50 mV
XG 20-848 mV150 mA50 mV
XG 33-508 mV120 mA50 mV
XG 40-428 mV90 mA50 mV
XG 60-288 mV70 mA50 mV
XG 80-218 mV50 mA80 mV
XG 100-178 mV40 mA80 mV
XG 150-11.210 mV32 mA100 mV
XG 300-5.625 mV20 mA150 mV
XG 600-2.850 mV12 mA250 mV
1. Maximum output voltage is guaranteed to be ≤ 0.2% of the rated voltage at zero output setting, using the front panel or digital remote programming modes.
2. Maximum output current is guaranteed to be ≤ 0.4% of the rated current at zero output setting, using the front panel or digital remote programming modes, and when measured with rated load resistance.
3. Total output power is also based on AUX1 Output Voltage (5 V) and AUX1 Output Current (0.5 A) and AUX2 Output Voltage (15 V) and AUX2 Output Current (0.5 A).
4. From 85–132 Vac or 170–265 Vac, constant load.
5. From 85–132 Vac or 170–265 Vac, constant load.
6. From no load to full load, constant input voltage.
7. For load voltage change, equal to the unit voltage rating, constant input voltage.
8. For 6 V models the current ripple is measured at 2–6 V output voltage and full output current. For all other models, the current ripple is measured at 10–100% output voltage and full output current.

Note: All specifications are subject to change.
Output Ratings
ModelMaximum Recommended Remote Sense Line Drop Compensation per Line 9Up-prog. Response Time, 0~Vmax 10Efficiency (100/200 VAC input) 11
XG 6-2201 V60 ms75/77%
XG 8-2001 V60 ms77/78%
XG 12-1401 V60 ms80/83%
XG 20-841.5 V60 ms82/85%
XG 33-502 V60 ms83/86%
XG 40-422 V60 ms83/87%
XG 60-283 V60 ms83/87%
XG 80-215 V100 ms83/87%
XG 100-175 V100 ms83/87%
XG 150-11.25 V100 ms83/87%
XG 300-5.65 V150 ms83/87%
XG 600-2.85 V250 ms83/87%
Output Ratings
ModelDown-prog. Response Time: Full LoadDown-prog. Response Time: No LoadOver-Voltage Trip Point
XG 6-22050 ms300 ms0.5–7.5 V
XG 8-20050 ms400 ms0.5–10 V
XG 12-14050 ms500 ms1–15 V
XG 20-8450 ms600 ms1–24 V
XG 33-5050 ms700 ms2–39 V
XG 40-4250 ms800 ms2–44 V
XG 60-2850 ms900 ms3–66 V
XG 80-2180 ms1000 ms3–95 V
XG 100-17100 ms1200 ms3–125 V
XG 150-11.2150 ms1800 ms3–180 V
XG 300-5.6150 ms2200 ms5–330 V
XG 600-2.8250 ms3500 ms5–660 V
9. When using remote sense, the total of the load voltage and the load line drops must not exceed the rated output of the power supply. For example, for an XG 6-220 in an application with 1 V of load line loss (0.5 V/Line), the maximum available load voltage would be 6-1=5 V. Note: The unit may operate at higher output voltages than this, but there is no guarantee That the power supply will meet performance specifications. Ultimately, the upper limit of the output voltage will be determined by internal circuitry of the power supply (non-adjustable) 
10. With rated, resistive load. 
11. At 100/200 Vac input voltage and maximum output power. Applies to all footnotes: Programming and Readback: RS-232, RS-485, USB built in. GP1B, Ethernet optional. Specifications are guaranteed from 1% to 100% of the rated output voltage, current, and power. 
* Typical 

Note: All specifications are subject to change.
AC Line Input Specifications
Rated AC Input Voltage/Frequency100–240 Vac, 47–63 Hz
Operational AC Input Voltage/Frequency85–265 Vac continuous, 47–63 Hz, single phase
Input Current (at 100/200 Vac)23/12 A
Inrush Current (100/200 Vac)Less than: 50 A
Power Factor Correction0.99@100/200 Vac, rated output power
Programming Mode

APGISOLDIGITAL
Voltage & Current Output Voltage Programming0-100% 2~up to 10 V, programmable

Voltage & Current Output Resistive Programming0-100% 2~up to 10 kΩ, programmable

Voltage Output Resistor Programming0-100% 2~up to 10 kΩ, programmable

Output Voltage and Current Monitor0-100% 2~up to 10 V, programmable

Voltage Programming Accuracy (mV)1± 0.5% of rated output voltage, max (0-4V/4K range)
± 0.1% of rated output voltage
Current Programming Accuracy (mV)1± 1% of rated output current, max (0-4V/4K range)
± 0.2% of rated output current
Voltage Readback Accuracy (mV)± 1% of rated output voltage
± 0.1% of rated output voltage
Current Readback Accuracy (mV)± 1% of rated output current
± 0.2% of rated output current
Isolation (Prog and Readback Lines)With respect to chassis potential: 500 VWith respect to: chassis potential: 600 V negative or positive main output 1500 V negative or positive auxiliary output 300 V
Voltage and Current Programming Resolution

0.012% of full scale
Voltage and Current Readback Resolution


Parallel OperationUp to 4 units in master / slaveUp to 4 units in master / slaveUp to 4 units in master / slave
Series Operation
Up to 2 units (with external diodes)Up to 2 units (with external diodes)
Constant Voltage (CV) Constant Current (CC) IndicatorCV: TTL High (4-5 V) 
CC TTL Low (0-0.6 V)


Shutdown Control 2
Logic low 0.0 - 1.4 V 
Logic high 2.0 - 15 V 
Dry contact compatible

AUX On/Off Control
TTL level or dry contact compatible
Power Supply Status Signal
TTL high: OK (4-5 V) 
TTL low: fail (0-0.6 V)

Interlock Enable/Disable
Dry contact. Open/Short: On or Off programmable
1. Typical APG or isolated APG accuracy can be improved to max accuracy by user calibration at the specific range selected 
2. The shutdown input has user selectable negative logic operation via front panel or remote digital input/output 

Note: All specifications are subject to change.
Output Performance Specifications
Temperature Coefficient100 PPM/° C from rated output voltage, after a 30-minute warm-up*
Drift (8 hours)0.05% of rated output voltage & current over an 8 hour interval with constant line, load & temperature, after a 30-minute warm-up
Hold-up TimeTypical 20 ms at any rated input line.
Transient Response Time 1Less than 1 ms for 6 V to 60 V models. Less than 2 ms for 80 V to 600 V models*
Meter Accuracy0.5% ± 1 count
Aux output 3+5 V: +0.4 V, – 0.5 V at 0.4 A
+15 V: +1.2 V, – 1.4 V at 0.4 A
Isolation 21500Vac or 2121Vdc between mains terminals and accessible conductive parts / chassis ground. 
Output to chassis 500Vac.
Environmental Specifications (Indoor use)
Operating Temperature Range32°F to 122°F, 100% load (0°C to 50°C)
Storage Temperature Range-4°F to 158°F (–20° C to 70°C)
Operating Humidity Range30–90% RH (no condensation)
Storage Humidity Range10–95% RH (no condensation)
Operating AltitudeUp to 6,500 feet (2,000 m)
Installation CategoryII (IEC 1010-1)
Pollution Degree2 (IEC 1010-1)
Mechanical Specifications
XG 1700 Watt (W×H×D)16.8 x 1.7 x 19.0 inch (429 x 43.6 x 483 mm without rack mount ears)
Weight22 lb (10 kg)
CoolingForced air cooling by internal fans
Regulatory Approvals
Safety
 
CSA 22.2 No. 61010-1, 60950-1-07 and UL61010-1, UL60950-1-(2nd Ed) 12 12. Marked with cCSAus, CE for EMC & low voltage directive
EMCComplies with EN61326-1 
Complies with EN55022, Class B, FCC Part 15B for conducted emissions 
Complies with EN55022, Class A, FCC Part 15A for radiated emissions 
Complies with EN61000-4 series of standards for immunity

* Typical
1. Time for the output voltage to recover within 0.05% at its rated output for a load change 10-90% of rated ouput current. Output set point 10-100%
2. Double insulation on primary to secondary isolation barriers. Basic insulation primary to protective earth ground.
3. Current: 0.51 A minimum guaranteed, 0.72 A typically available. Overcurrent protection (each output) is automatic, non-latching. When OCP is tripped the aux voltage folds back and will recover to nominal condition
when the over current condition is removed (typ. <0.2A). To protect external circuits attached to the aux outputs it is recommended that customers use an appropriately rated fuse in series with the aux outputs set point 10-100%

Note: All specifications are subject to change.