聯絡我們:07-9738888
產品介紹

Sorensen XFR Series

產品名稱:2.8 kilowatt DC power supply ideal for applications產品型號:Sorensen XFR SeriesSorensen XFR Series2.8 kilowatt DC power supply ideal for applications where high power and a wide adjustment of output voltage or current is requiredProduct OverviewXFR is the smart choice for research,

產品介紹

產品名稱:2.8 kilowatt DC power supply ideal for applications

產品型號:Sorensen XFR SeriesSorensen XFR Series
2.8 kilowatt DC power supply ideal for applications where high power and a wide adjustment of output voltage or current is required

Product Overview 
XFR is the smart choice for research, product development and production test applications such as R&D, magnet control, product design, ATE, process control, electroplating and burn-in. The unique features of XFR make it the best choice for applications where high power and a wide adjustment of output voltage or current are required in a full 19-inch rack package. Choose from ten 2800-watt models. 

Zero voltage, or "soft" switching, provides significant benefits. Switching transients are virtually eliminated and noise performance is closer to linear levels. Efficiency is increased, heat generation is decreased, and stress on the switching transistors is reduced - improving reliability (MTBF). Unlike most competitive products, XFR generates full power at full rated current over its total operating range of 0 to 50° C without derating. XFR is also designed with excellent thermal management, so units can be stacked in rack mounts without leaving ventilation space between each unit.

Features And Benefits

● Analog Programming
● Constant Voltage or Constant Current Operation
● LabView® and LabWindows® Drivers
● Standby Mode
● Front Panel Button Preview of Voltage, Current, OVP
● CE, CSA, UL Approvals

Specifications


Common
Switching FrequencyXFR 2.8 kW: Nominal 31 kHz (62 kHz output ripple); 60 V to 600 V models: nominal 62.5 kHz (125 kHz output ripple).
Time Delay7 sec maximum from power on until output stable
Voltage Mode Transient Response Time< 3 ms for output voltage to recover within 0.5% of its rated voltage after a step change in load current of up to 10% to 90% of rated output
Maximum Voltage Differential±600 Vdc from output to safety ground
Remote Start/Stop and Interlock2.5-15 V signal or TTL-compatible input, selectable logic
Remote Analog ProgrammingVoltage and current programming inputs (source must be isolated): 0-5 k, 0-10 k resistances; 0-5 V, 0-10 V (default) voltage sources
Remote Analog MonitoringVoltage and current monitor outputs 0-5 V, 0-10 V (default) ranges for 0-100% of output
Remote Programming & Monitoring Accuracy1% zero to full scale output for the default range
Maximum Remote Sense Line Drop Compensation5 V / line (Line drop is subtracted from total voltage available at supply output.)
Front Panel Voltage and Current Control10-turn voltage and current potentiometers
Front Panel Voltage Control Resolution0.02% of maximum voltage
Main Output ConnectorXFR 2.8 kW: 7.5 - 100 V models: nickel-plated copper bus bars with bus bar cover and strain relief; 150V to 600 V models: 4-terminal, wire clamp connector with cover and strain relief
ApprovalsNRTL approved and CE-marked to UL Std. No. 61010-1, CAN/CSA-C22.2 No. 61010-1-04, EN 610101-1 (Equipment Class I, Pollution Degree 2, Installation Category II) Meets USA EMC standard: FCC, part 15B, Class A; Meets Canadian EMC standard: ICES-001, Class A.
Input
Input Voltage RangesXFR 2.8 kW: 190-264 Vac, 1φ (24.3 A @ 208 Vac; 20.5 A @ 230 Vac typical), 47-63 Hz; Option: M2 3φ 208 Vac input
AC Input ConnectorType 3-terminal, 34 A, 250 V, wire clamp connector with strain relief cover
Protection Features
Over-voltage protection
Over-temperature protection
Environmental
Operating TemperatureXFR 2.8 kW: 0 to 50°C,
Storage Temperature-20°C to 70°C
Humidity (Non-condensing)Up to 90% RH, non-condensing
Physical
ModelXFR 2.8 kW
DimensionsWidth: 19” (429.4 mm)
Height: 3.5” (88.9 mm)
Depth: 21” (533.5 mm

Weight33 lb (15 kg)
Output Ratings
ModelOutput VoltageOutput CurrentOutput Power
XFR 7.5-3000-7.5 V0-300 A2250 W
XFR 12-2200-12 V0-220 A2640 W
XFR 20-1300-20 V0-130 A2600 W
XFR 33-850-33 V0-85 A2805 W
XFR 40-700-40 V0-70 A2800 W
XFR 60-460-60 V0-46 A2760 W
XFR 100-280-100 V0-28 A2800 W
XFR 150-180-150 V0-18 A2700 W
XFR 300-90-300 V0-9 A2700 W
XFR 600-40-600 V0-4 A2400 W
Line Regulation
ModelVoltageCurrent
XFR 7.5-3002.75 mV32 mA
XFR 12-2203.2 mV24 mA
XFR 20-1304 mV15 mA
XFR 33-855.3 mV10.5 mA
XFR 40-706 mV9 mA
XFR 60-468 mV6.6 mA
XFR 100-2812 mV4.8 mA
XFR 150-1817 mV3.8 mA
XFR 300-932 mV2.9 mA
XFR 600-462 mV2.4 mA
Load Regulation
ModelVoltageCurrent
XFR 7.5-3006.5 mV65 mA
XFR 12-2207.4 mV49 mA
XFR 20-1309 mV31 mA
XFR 33-8511.6 mV22 mA
XFR 40-7013 mV19 mA
XFR 60-4617 mV14.2 mA
XFR 100-2827 mV10.6 mA
XFR 150-1835 mV8.6 mA
XFR 300-965 mV6.8 mA
XFR 600-4125 mV5.8 mA
Meter Accuracy
ModelVoltage (1% of Vmax + 1 count)Current (1% of lmax + 1 count)
XFR 7.5-3000.09 V4 A
XFR 12-2200.13 V2.3 A
XFR 20-1300.3 V1.4 A
XFR 33-850.43 V0.95 A
XFR 40-700.5 V0.8 A
XFR 60-460.7 V0.56 A
XFR 100-281.1 V0.38 A
XFR 150-181.6 V0.19 A
XFR 300-94 V0.1 A
XFR 600-47 V0.05 A
Output Ratings
ModelOutput Noise (0-20 MHz)Output Ripple (rms)
Voltage (p-p)VoltageCurrent
XFR 7.5-300100 mV10 mV1600 mA
XFR 12-220100 mV10 mV1200 mA
XFR 20-130100 mV10 mV400 mA
XFR 33-85100 mV15 mV300 mA
XFR 40-70150 mV15 mV200 mA
XFR 60-46150 mV15 mV100 mA
XFR 100-28175 mV25 mV80 mA
XFR 150-18200 mV25 mV40 mA
XFR 300-9400 mV40 mV20 mA
XFR 600-4500 mV100 mV10 mA
Output Ratings
ModelDrift (8 hours)
Voltage (0.5% of Vmax)Current (0.05% of lmax)
XFR 7.5-3003.75 mV150 mA
XFR 12-2206 mV110 mA
XFR 20-13010 mV65 mA
XFR 33-8516.5 mV42.5 mA
XFR 40-7020 mV35 mA
XFR 60-4630 mV23 mA
XFR 100-2850 mV14 mA
XFR 150-1875 mV9 mA
XFR 300-9150 mV4.5 mA
XFR 600-4300 mV2 mA
Output Ratings
ModelTemp Coeffcient
Voltage (0.02% of Vmax ºC)Current (0.03% of Vmax ºC)
XFR 7.5-3001.5 mV90 mA
XFR 12-2202.4 mV66 mA
XFR 20-1304 mV39 mA
XFR 33-856.6 mV25.5 mA
XFR 40-708 mV21 mA
XFR 60-4612 mV13.8 mA
XFR 100-2820 mV8.4 mA
XFR 150-1830 mV5.4 mA
XFR 300-960 mV2.7 mA
XFR 600-4120 mV1.2 mA
Output Ratings
ModelProgram Slew Rate
Rise timeFall time
XFR 7.5-300100 ms100 ms
XFR 12-220100 ms100 ms
XFR 20-130100 ms100 ms
XFR 33-85100 ms100 ms
XFR 40-70100 ms100 ms
XFR 60-46100 ms100 ms
XFR 100-28170 ms170 ms
XFR 150-18170 ms170 ms
XFR 300-9170 ms170 ms
XFR 600-4170 ms170 ms
Output Ratings
ModelOVP Adjustment Range 
(5% to 110% of Vmax)
Efficiency
XFR 7.5-3000.375-8.25 V80%
XFR 12-2200.6-13.2 V82%
XFR 20-1301-22 V85%
XFR 33-851.65 - 36.6 V85%
XFR 40-702-44 V87%
XFR 60-463-66 V90%
XFR 100-285-110 V90%
XFR 150-187.5-165 V90%
XFR 300-915-330 V91%
XFR 600-430-660 V91%
Interface Specifications with RS-232 or GPIB Interface Installed
ModelProgram Accuracy
Voltage (mV)Current (mA)OVP (mV)
XFR 7.5-30010 +0.12%900 +0.15%40
XFR 12-22075 +0.12%750 +0.15%75
XFR 20-13075 +0.12%500 +0.15%100
XFR 33-8575 +0.3%425 +0.1%175
XFR 40-7075 +0.3%350 +0.15%200
XFR 60-46150 +0.3%250 +0.1%300
XFR 100-28150 +0.35%140 +0.15%500
XFR 150-18225 +0.35%120 +0.1%750
XFR 300-9225 +0.35%80 +0.1%1500
XFR 600-4300 +0.35%80 +0.1%3000
Interface Specifications with RS-232 or GPIB Interface Installed
ModelReadback Accuracy
Voltage (mV)Current (mA)
XFR 7.5-30030 +0.12%900 +0.1%
XFR 12-22075 +0.12%750 +0.1%
XFR 20-13075 +0.2%500 +0.1%
XFR 33-8575 +0.3%425 +0.1%
XFR 40-7075 +0.3%350 +0.1%
XFR 60-46150 +0.35%250 +0.1%
XFR 100-28150 +0.35%140 0.1%
XFR 150-18225 +0.35%120 +0.1%
XFR 300-9225 +0.35%80 +0.1%
XFR 600-4300 +0.35%80 +0.1%


產品型錄下載