聯絡我們:07-9738888
產品介紹

Sorensen DCS Series

產品名稱:(1k,1.2k, 3kW) switching power supplies產品型號:Sorensen DCS SeriesSorensen DCS Series1kW, 1.2kW and 3kW switching power supplies that achieve continuous full output power in any volt/amp combination within a low profile chassisProduct OverviewThe DCS Family of 1 kW, 1.2 kW and 3 kW

產品介紹

產品名稱:(1k,1.2k, 3kW) switching power supplies

產品型號:Sorensen DCS SeriesSorensen DCS Series
1kW, 1.2kW and 3kW switching power supplies that achieve continuous full output power in any volt/amp combination within a low profile chassis

Product Overview 
The DCS Family of 1 kW, 1.2 kW and 3 kW programmable power supplies utilizes unique packaging techniques to achieve continuous full output power (1 kW, 1.2 kW or 3 kW) in any volt/amp combination within the rated output voltage and current limits in a low profile chassis., Demonstrated large installed base over a long period of time, the DCS family provides a highly reliable power platform. 

This family has an easy-to-use front panel with 10-turn potentiometers to adjust voltage and current settings that are displayed simultaneously. LEDs indicate overtemperature, remote programming, shutdown and over voltage protection, status and constant-voltage/current mode operation. The DCS 3 kW Models have push button control of the output standby mode, OVP reset, remote/local programming and preview status of voltage, current and OVP setpoints. 

The DCS family can also be controlled remotely. Four analog control modes are standard as well as isolated analog control (option). Computer control can be accomplished over IEEE488.2 GPIB (option) or LXI-compliant Ethernet (option)

Features And Benefits
Wide Voltage Ranges
From 0-8 VDC to 0-600 VDC; current levels from 1.7A to 350A

East Master/Slave Paralleling with Active Current Sharing

5 Year Warranty

Remote Programming

● Selectable remote programming for voltage, current and OVP
● 16 bit programming through LXI -compliant Ethernet LAN / RS-232C (M130)
● 12-bit programming through IEEE-488.2 / RS-232C (Option M9C)Isolated analog programming (Option M51)
● Multichannel slave interface (Option M85 or M131)

Software

● IVI-com driver for M130 option
● Labwindows CVI driver for M9C option
● Labview driver for M9C option

Specifications


Common
Meter Accuracy1% of full scale + 1 count
Max. Voltage Differential from Output to Safety Ground150 VDC
Remote Start/Stop and InterlockTTL compatible input or 12-250 VAC (12-130 VDC) or a contact closure
CoolingInternal fan, over temperature shutdown if internal heat sink exceeds set temperature
Remote SenseThe maximum allowed sense line drop is 4V per line (2V on the DCS 8/10V 1 kW/1.2 kW models and 1V/line for all 3 kW models). Line drop subtracts from the maximum available output voltage at full rated power.
Remote ProgrammingEnabled via external jumper on rear panel connector J3
Overvoltage ProtectionCrowbar type adjustable from 5-110% of rated output using front panel control (local or remote program selectable via J3 jumper)
Remote Analog Programming LinearityTypical error is less an 0.5% setting.
Accuracy is 1% of rated output.
RegulatoryCertified to UL/CSA 61010 and IEC/EN 61010-1 CE Compliant (LVD and EMC directive)
Input: Voltage and Frequency
Output Power200 - 250 VAC100 - 132 VAC190 - 250 VAC
1kWsingle phase, 8A typical, 47- 63 Hzsingle phase, 15A typical, 47-63 Hz, internal jumper selectable
1.2kWsingle phase, 9A typical, 47-63 Hzsingle phase, 18A typical, 47-63 Hz, internal jumper selectable
3kWsingle-phase, 20A, 47- 63Hz.
three phase, 14A, 47-63Hz.
Output: Voltage and Current
1kW ModelVoltageCurrent
DCS 8-125E0 - 80 - 125
DCS 10-100E0 - 100 - 100
DCS 20-50E0 - 200 - 50
DCS 33-33E0 - 330 - 33
DCS 40-25E0 - 400 - 25
DCS 50-20E0 - 500 - 20
DCS 60-18E0 - 600 - 18
DCS 80-13E0 - 800 - 13
DCS 100-10E0 - 1000 - 10
DCS 150-7E0 - 1500 -7
DCS 300-3.5E0 - 3000 - 3.5
DCS 600-1.7E0 - 6000 - 1.7
1.2kW ModelVoltageCurrent
DCS 8-140E0 - 80 - 140
DCS 10-120E0 - 100 - 120
DCS 20-60E0 - 200 - 60
DCS 33-36E0 - 330 - 36
DCS 40-30E0 - 400 - 30
DCS 50-24E0 - 500 - 24
DCS 60-20E0 - 600 - 20
DCS 80-15E0 - 800 - 15
DCS 100-12E0 - 1000 - 12
DCS 150-8E0 - 1500 - 8
DCS 300-4E0 - 3000 - 4
3kW ModelVoltageCurrent
DCS 8-350E0 - 80 - 350
DCS 12-250E0 - 120 - 250
DCS 20-150E0 - 200 - 150
DCS 40-75E0 - 400 - 75
DCS 55-55E0 - 550 - 55
DCS 60-50E0 - 600 - 50
DCS 80-37E0 - 800 - 37
DCS 150-20E0 - 1500 - 20
Output
Voltage Resolution0.02%
Ripple (mV rms or p-p)See table
Regulation LineFor input voltage variation over the AC input voltage range, with constant rated load.
LoadFor 0-100% load variation, with constant nominal line voltage.
Voltage0.1%
Current0.1%
Transient ResponseTypically recovers in 500 μs (1 & 1.2 kW) or 1ms (3k W) to 1% of steady-state output voltage (within 1% of Vmax) for 70-100% or 100-70% load change.
Stability±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature
EfficiencySee table below Temperature Coefficient: 0.02%/°C of maximum output voltage; 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load
Physical
Dimensions

Width: 19” (482 mm) W, Depth 17.52” (445 mm)

Height: 1 kW and 1.2 kW: 1U or 1.72” (43 mm) 3 kW: 2U or 3.46” (87 mm)

Weight & Shipping Weight
Weight1 kW and 1.2 kW: 19 lbs. ( 8.6 kg) 
3 kW: 33 lbs. (15 kg)
Shipping Weight1 kW and 1.2 kW: 24 lbs. (10.9 kg) 
3 kW: 42 lbs. (19 kg)
Environmental
Operating Temperature0°C to 50°C (no derating)
Storage Temperature-55°C to 85°C
Humidity Range0 to 80% RH, non condensing
Programming Specifications
DCS Series 1 kWProgramming Accuracy M130/M131/M9C/M85 Options
Voltage 0.1% +Current 0.1% +OVP 0.5% +
DCS 8-125E8mV500mA44mV
DCS 10-100E10mV400mA55mV
DCS 20-50E20mV200mA110mV
DCS 33-33E33mV132mA182mV
DCS 40-25E40mV100mA220mV
DCS 50-20E50mV80mA275mV
DCS 60-18E60mV72mA330mV
DCS 80-13E80mV52mA440mV
DCS 100-10E100mV40mA550mV
DCS 150-7E150mV20mA825mV
DCS 300-3.5E300mV15mA1650mV
DCS 600-1.7E600mV6.8mA3300mV
DCS Series 1.2 kWProgramming Accuracy M130/M131/M9C/M85 Options
Voltage 0.1% +Current 0.1% +OVP 0.5% +
DCS 8-140E8mV560mA44mV
DCS 10-120E10mV480mA55mV
DCS 20-60E20mV240mA110mV
DCS 33-36E23mV144mA182mV
DCS 40-30E40mV120mA220mV
DCS 50-24E50mV96mA275mV
DCS 60-20E60mV80mA330mV
DCS 80-15E80mV60mA440mV
DCS 100-12E100mV48mA550mV
DCS 150-8E150mV32mA825mV
DCS 300-4E300mV16mA1650mV
DCS Series 3 kWProgramming Accuracy M130/M131/M9C/M85 Options
Voltage 0.1% +Current 0.1% +OVP 0.5% +
DCS 8-350E8mV1400mA44mV
DCS 12-250E12mV1000mA66mV
DCS 20-150E20mV600mA110mV
DCS 40-75E40mV300mA220mV
DCS 55-55E55mV220mA303mV
DCS 60-50E60mV200mA330mV
DCS 80-37E80mV148mA440mV
DCS 150-20E150mV80mA825mV
Read-back Specifications
DCS Series 1 kWReadback Accuracy
Voltage 0.1% +Current 0.1% +
DCS 8-125E12mV500mA
DCS 10-100E15mV400mA
DCS 20-50E30mV200mA
DCS 33-33E50mV132mA
DCS 40-25E60mV100mA
DCS 50-20E75mV80mA
DCS 60-18E90mV72mA
DCS 80-13E120mV52mA
DCS 100-10E150mV40mA
DCS 150-7E225mV28mA
DCS 300-3.5E450mV14mA
DCS 600-1.7E900mV7mA
DCS Series 1.2 kWReadback Accuracy
Voltage 0.1% +Current 0.1% +
DCS 8-140E12mV560mA
DCS 10-120E15mV480mA
DCS 20-60E30mV240mA
DCS 33-36E50mV144mA
DCS 40-30E60mV120mA
DCS 50-24E75mV95mA
DCS 60-20E90mV80mA
DCS 80-15E120mV60mA
DCS 100-12E150mV48mA
DCS 150-8E225mV32mA
DCS 300-4E450mV16mA
DCS Series 3 kWReadback Accuracy
Voltage 0.1% +Current 0.1% +
DCS 8-350E12mV1400mA
DCS 12-250E18mV1000mA
DCS 20-150E30mV600mA
DCS 40-75E60mV300mA
DCS 55-55E83mV220mA
DCS 60-50E90mV200mA
DCS 80-37E120mV148mA
DCS 150-20E225mV80mA
Output
DCS Series 1 kWOutput Power
Voltage VDCCurrent ADC @ 50°C
DCS 8-125E0-80-125
DCS 10-100E0-100-100
DCS 20-50E0-200-50
DCS 33-33E0-330-33
DCS 40-25E0-400-25
DCS 50-20E0-500-20
DCS 60-18E0-600-18
DCS 80-13E0-800-13
DCS 100-10E0-1000-10
DCS 150-7E0-1500-7
DCS 300-3.5E0-3000-3.5
DCS 600-1.7E0-6000-1.7
DCS Series 1.2 kWOutput Power
Voltage VDCCurrent ADC @ 50°C
DCS 8-140E0-80-140
DCS 10-120E0-100-120
DCS 20-60E0-200-60
DCS 33-36E0-330-36
DCS 40-30E0-400-30
DCS 50-24E0-500-24
DCS 60-20E0-600-20
DCS 80-15E0-800-15
DCS 100-12E0-1000-12
DCS 150-8E0-1500-8
DCS 300-4E0-3000-4
DCS Series 3 kWOutput Power
Voltage VDCCurrent ADC @ 50°C
DCS 8-350E0-80-350
DCS 12-250E0-120-250
DCS 20-150E0-200-150
DCS 40-75E0-400-75
DCS 55-55E0-550-55
DCS 60-50E0-600-50
DCS 80-37E0-800-37
DCS 150-20E0-1500-20
Output
DCS Series 1 kWConstant Voltage Mode*
Ripple** (rms) mVNoise** (p-p) mVTransient Response
time μs (typ)
DCS 8-125E460500
DCS 10-100E460500
DCS 20-50E460500
DCS 33-33E460500
DCS 40-25E460500
DCS 50-20E460500
DCS 60-18E460500
DCS 80-13E460500
DCS 100-10E460500
DCS 150-7E12160500
DCS 300-3.5E20200500
DCS 600-1.7E50300500
DCS Series 1.2 kWConstant Voltage Mode*
Ripple (rms) ** mVNoise (p-p) mVTransient Response
time μs (typ)
DCS 8-140E560500
DCS 10-120E5560500
DCS 20-60E560500
DCS 33-36E560500
DCS 40-30E560500
DCS 50-24E560500
DCS 60-20E560500
DCS 80-15E560500
DCS 100-12E1060500
DCS 150-8E15160500
DCS 300-4E25200500
DCS Series 3 kWConstant Voltage Mode*
Ripple (rms) ** mVNoise (p-p) mVTransient Response
time μs (typ)
DCS 8-350E151001000
DCS 12-250E101001000
DCS 20-150E101001000
DCS 40-75E201001000
DCS 55-55E201001000
DCS 60-50E201001000
DCS 80-37E201001000
DCS 150-20E302001000
* Typical resolution is 0.02% ** Typical P-P noise and ripple (20Hz to 300kHz)
Output
DCS Series 1 kWCombined Regulation Line and Load %Temp Coeff. Voltage %Voltage Drift 
% Vmax (typ)
DCS 8-125E0.20.020.05
DCS 10-100E0.20.020.05
DCS 20-50E0.20.020.05
DCS 33-33E0.20.020.05
DCS 40-25E0.20.020.05
DCS 50-20E0.20.020.05
DCS 60-18E0.20.020.05
DCS 80-13E0.20.020.05
DCS 100-10E0.20.020.05
DCS 150-7E0.20.020.05
DCS 300-3.5E0.20.020.05
DCS 600-1.7E0.20.020.05
DCS Series 1.2 kW


Combined Regulation Line and Load %Temp Coeff. Voltage %Voltage Drift 
% Vmax (typ)
DCS 8-140E0.20.020.05
DCS 10-120E0.20.020.05
DCS 20-60E0.20.020.05
DCS 33-36E0.20.020.05
DCS 40-30E0.20.020.05
DCS 50-24E0.20.020.05
DCS 60-20E0.20.020.05
DCS 80-15E0.20.020.05
DCS 100-12E0.20.020.05
DCS 150-8E0.20.020.05
DCS 300-4E0.20.020.05
DCS Series 3 kW


Combined Regulation Line and Load %Temp Coeff. Voltage %Voltage Drift 
% Vmax (typ)
DCS 8-350E0.20.020.05
DCS 12-250E0.20.020.05
DCS 20-150E0.20.020.05
DCS 40-75E0.20.020.05
DCS 55-55E0.20.020.05
DCS 60-50E0.20.020.05
DCS 80-37E0.20.020.05
DCS 150-20E0.20.020.05
Output
DCS Series 1 kWProgramming Constraints Voltage Mode
Ohms / V

V / V


DCS 8-125E6250-10V = 0-100% V, or 0-5V = 0-100% V
DCS 10-100E500
DCS 20-50E250
DCS 33-33E151.5
DCS 40-25E125
DCS 50-20E100
DCS 60-18E83
DCS 80-13E62.5
DCS 100-10E50
DCS 150-7E33.3
DCS 300-3.5E16.67
DCS 600-1.7E8.33
DCS Series 1.2 kWProgramming Constraints Voltage Mode
Ohms / V

V / V

DCS 8-140E6250-10V = 0-100% V, or 0-5V = 0-100% V
DCS 10-120E500
DCS 20-60E250
DCS 33-36E151.5
DCS 40-30E125
DCS 50-24E100
DCS 60-20E83
DCS 80-15E62.5
DCS 100-12E50
DCS 150-8E33.3
DCS 300-4E16.67
DCS Series 3 kWProgramming Constraints Voltage Mode
Ohms / V

V / V

DCS 8-350E6250-10V = 0-100% V, or 0-5V = 0-100% V
DCS 12-250E416.7
DCS 20-150E250
DCS 40-75E125
DCS 55-55E90.9
DCS 60-50E83
DCS 80-37E62.5
DCS 150-20E33.3
Output
DCS Series 1 kWConstant Current Mode*
Regulation line and load % combined

Ripple (rms)** mA


DCS 8-125E0.2160
DCS 10-100E0.2128
DCS 20-50E0.225
DCS 33-33E0.210
DCS 40-25E0.27
DCS 50-20E0.27
DCS 60-18E0.26
DCS 80-13E0.24
DCS 100-10E0.23
DCS 150-7E0.22
DCS 300-3.5E0.21
DCS 600-1.7E0.21
DCS Series 1.2 kWConstant Current Mode*
Regulation line and load % combined

Ripple (rms)** mA

DCS 8-140E0.2180
DCS 10-120E0.2153
DCS 20-60E0.230
DCS 33-36E0.211
DCS 40-30E0.29
DCS 50-24E0.28.5
DCS 60-20E0.26.6
DCS 80-15E0.26
DCS 100-12E0.23.6
DCS 150-8E0.22.3
DCS 300-4E0.21.2
DCS Series 3 kWConstant Current Mode*
Regulation line and load % combined

Ripple (rms)** mA

DCS 8-350E0.2
DCS 12-250E0.2
DCS 20-150E0.2
DCS 40-75E0.2
DCS 55-55E0.2
DCS 60-50E0.2
DCS 80-37E0.2
DCS 150-20E0.2
Output
DCS Series 1 kW


Temp. Coeff. % °C (typ)

Current Drift %| out Max (typ.)


DCS 8-125E0.030.05
DCS 10-100E0.030.05
DCS 20-50E0.030.05
DCS 33-33E0.030.05
DCS 40-25E0.030.05
DCS 50-20E0.030.05
DCS 60-18E0.030.05
DCS 80-13E0.030.05
DCS 100-10E0.030.05
DCS 150-7E0.030.05
DCS 300-3.5E0.030.05
DCS 600-1.7E0.030.05
DCS Series 1.2 kW

Temp. Coeff. % °C (typ)

Current Drift %| out Max (typ.)

DCS 8-140E0.030.05
DCS 10-120E0.030.05
DCS 20-60E0.030.05
DCS 33-36E0.030.05
DCS 40-30E0.030.05
DCS 50-24E0.030.05
DCS 60-20E0.030.05
DCS 80-15E0.030.05
DCS 100-12E0.030.05
DCS 150-8E0.030.05
DCS 300-4E0.030.05
DCS Series 3 kW

Temp. Coeff. % °C (typ)

Current Drift %| out Max (typ.)

DCS 8-350E0.030.05
DCS 12-250E0.030.05
DCS 20-150E0.030.05
DCS 40-75E0.030.05
DCS 55-55E0.030.05
DCS 60-50E0.030.05
DCS 80-37E0.030.05
DCS 150-20E0.030.05
Output
DCS Series 1 kWProgramming Constants, Current Mode
Ohms/A

V/A


DCS 8-125E400-10V = 0-100% |a or 0-5V = 0-100% |a
DCS 10-100E50
DCS 20-50E100
DCS 33-33E151.5
DCS 40-25E200
DCS 50-20E250
DCS 60-18E277.8
DCS 80-13E384.6
DCS 100-10E500
DCS 150-7E714.3
DCS 300-3.5E1428.6
DCS 600-1.7E2941.2
DCS Series 1.2 kWProgramming Constants, Current Mode
Ohms/A

V/A

DCS 8-140E35.70-10V = 0-100% |a or 0-5V = 0-100% |a
DCS 10-120E41.7
DCS 20-60E83.3
DCS 33-36E138.9
DCS 40-30E166.7
DCS 50-24E208.3
DCS 60-20E250.0
DCS 80-15E333.3
DCS 100-12E416.7
DCS 150-8E625.0
DCS 300-4E1250.0
DCS Series 3 kWProgramming Constants, Current Mode
Ohms/A

V/A

DCS 8-350E
0-10V = 0-100% |a or 0-5V = 0-100% |a
DCS 12-250E
DCS 20-150E
DCS 40-75E
DCS 55-55E
DCS 60-50E
DCS 80-37E
DCS 150-20E
Output
DCS Series 1 kWInput Current, A NominalEfficiency % (Typ.)
230V Single Phase208V Three Phase
DCS 8-125E8N/A82
DCS 10-100E8N/A82
DCS 20-50E8N/A82
DCS 33-33E8N/A84
DCS 40-25E8N/A84
DCS 50-20E8N/A84
DCS 60-18E8N/A86
DCS 80-13E8N/A86
DCS 100-10E8N/A86
DCS 150-7E8N/A86
DCS 300-3.5E8N/A86
DCS 600-1.7E9.5N/A86
DCS Series 1.2 kW


Input Current, A NominalEfficiency % (Typ.)
230V Single Phase208V Three Phase
DCS 8-140E9N/A82
DCS 10-120E9N/A82
DCS 20-60E9N/A82
DCS 33-36E9N/A84
DCS 40-30E9N/A84
DCS 50-24E9N/A84
DCS 60-20E9N/A85
DCS 80-15E9N/A85
DCS 100-12E9N/A85
DCS 150-8E9N/A85
DCS 300-4E9N/A85
DCS Series 3 kW


Input Current, A NominalEfficiency % (Typ.)
230V Single Phase208V Three Phase
DCS 8-350E241382
DCS 12-250E261482
DCS 20-150E261482
DCS 40-75E261486
DCS 55-55E261482
DCS 60-50E261486
DCS 80-37E261486
DCS 150-20E261486
* Typical resolution is 0.02% ** rms ripple typical from 20 Hz to 300 kHz

 

J3 Connector
190-250 VAC Remote Shutdown14TTL Shutdown
2Shutdown Return15+12 VDC
3OVP Program161 mACurrent Source (OVP)
4Remote/Local Status Indicator17OVP Indicator
5Mode Status Indicator18Thermal S/DN Status
6Ground190-5V Voltage Monitor
70-5V Current Monitor20Remote Voltage Select
8Voltage Control211 mA Current Source (V)
9Voltage Program Input221 mA Current Source (I)
10Current Program Unit231 mA Current Source (I)
11Current Control24Return
12Return Sense25POS Output (8-100V Models Only)
13POS Sense (8-100V Models Only)


產品型錄下載