產品名稱:(3k, 4kW) programmable DC power supplies產品型號:Sorensen DLM SeriesSorensen DLM Series3kW and 4kW programmable DC power supplies that provide highly stable, continuously variable output voltage and current for a broad range of applications in a 2U chassisProduct OverviewThe Sorense

產品介紹

產品名稱:(3k, 4kW) programmable DC power supplies

產品型號:Sorensen DLM SeriesSorensen DLM Series
3kW and 4kW programmable DC power supplies that provide highly stable, continuously variable output voltage and current for a broad range of applications in a 2U chassis

Product Overview 
The Sorensen DLM 3kW and 4kW Series programmable DC power supplies are designed to provide highly stable, continuously variable output voltage and current for a broad range of applications in a compact 2U ( 3½” high) chassis. 

Both the 3 kW and 4 kW models have output voltages from 0-5 VDC to 0-600 VDC and a current range from 0-5A to 0-450A. The output rms noise is as low as 10 mV. The output will recover to 1% of its steady-state voltage within 1 ms for a step load change of 100% to 70% or 70% to 100%. The front panel layout makes the series extremely easy to use. Control switches include: power on, enable/ standby and local/ remote. 

Displays and indicators show programmed set points and operational control status. The programmed voltage, current and overvoltage set points are displayed with two large 3½ digit LED displays. Operational Status LEDs indicate power on, shutdown, over temperature, overvoltage, constant current and voltage mode status. Control Status LEDs indicate front panel lockout, remote control and standby status. IEEE- 488.2 control LEDs indicate error, service request and remote address status. 

The 3 kW Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power. 

The 4 kW Models will accept 200*/208 VAC, three phase or optional 400 or 480 VAC three phase input power. 

*Operating temperature below 40°C

Features And Benefits
High Power Density
3 kW and 4 kW models, 2U (3½ inches) high, 19 inches wide; no top or bottom clearance spacing required

Wide Range of Output Voltages
3 kW and 4 kW outputs 0-5V, 8V, 16V, 32V, 40V, 60V, 80V, 150V, 300V and 600V

Preview Pushbutton
Overvoltage protection (OVP), voltage and current preview buttons allow viewing these set points at any time with or without the output enabled

Remote Voltage Sense
Sense leads are easily connected to a solderless connector

Remote Operation

● Standard analog programming
● Output enable/disable remotely
● Optional IEEE-488.2 and RS 232
● Optional optically isolated analog programming

Calibration
All models can be calibrated without removing the covers

Operating Modes
Constant voltage and constant current, with LED indicators

Parallel or Series Operation
Field configurable

Input Power Factor
0.95 typical (three phase for all models) 0.98 typical (single phase)

CE Mark

5 Year Warranty

Specifications

Common
Front Panel ControlsKnobs with 3½ digit digital displays to control output voltage and current settings. Power on/off switch, output enable/standby switch and local/remote switch. Voltage, current and overvoltage preview push buttons allow you to preview the programmed settings at any time; overvoltage limit is adjusted with a set screw accessible through the front panel.
Displays and IndicatorsVoltage and overvoltage setting 3½ digit LED display, current setting 3½ digit LED display. LED indicators for power on, shutdown, remote, overvoltage protection, overtemperature and front panel lockout, constant voltage and constant current modes. IEEE-488.2 indicators include error, SRQ and address (M9E option).
Overvoltage ProtectionOutput overvoltage (resets by cycling the enable/standby switch)
CoolingInternal fans with over temperature protection
Rear Panel Control/Monitor
Remote SenseThe maximum load line drop is up to the full voltage rating of the supply. The drop in the load leads subtracts from the maximum voltage available for the load except as follows: maximum rated voltage is available at the load and voltage regulation specifications apply for line drops of <2V for models rated 5V to 16V, and <5V for all other models.
Remote Sense ProtectionUnit will not be damaged due to misconnection of the remote sense leads
Remote ProgrammingVoltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5 VDC, 0-10 VDC, or 0-5 kΩ.
Remote MonitoringVoltage or current can be monitored with user-selectable ranges, 0-5 VDC or 0-10 VDC
Operational FeaturesMaster/slave parallel operation, up to 2 units can be connected in parallel with active current sharing control to within 10% of each supply. Series operation, up to 3 units of the same model type can be connected in series (consult manual). Negative terminal rated at 150 Vmax above ground
SoftwareLabVIEW® driver M9E/M85
Regulatory ComplianceCE Mark, 16-185 & 22-180 certified NRTL to EN 61010-1. Marked cCSAus
Environmental
Operating Temperature0°C to 50°C, no derating (<200 VAC range limited to 40°C maximum)
Storage Temperature-40°C to 65°C
Physical
DimensionsWidth: 19” (483 mm)
Height: 3.5” (88 mm)
Depth: 18” (508 mm)
Weight40 lbs. ( 18.2 kg )
Shipping Weight49 lbs. ( 22.3 kg )
Input

3 kW4 kW
Voltage Ranges180-264 VAC, 47-63 Hz,
(<200 VAC range limited to 40°C maximum)
180-264 VAC, 345-455 VAC, 432-528 VAC,
47-63 Hz
(<200 VAC range limited to 40°C maximum)

Phasessingle or three phasethree phase
Power Factor0.95 typical with three phase input,
0.98 typical with single phase input
0.95 typical with three phase input
Currentsingle phase, 21A rms;
three phase, 12A rms
180-264 VAC, 15A rms;
345-455 VAC, 8.5A rms;
432-528 VAC, 6.5A rms;

Output
Stability±0.05% of maximum voltage or current over 8 hours after 15 minute warm-up time at fixed line, load and temperature. Current accuracy for 5V, 8V, and 16V models is 1% typical.
Line RegulationFor input voltage variation over the AC input voltage range, with constant rated load.
Voltage: 0.05% of maximum rated output +2mV
Current: 0.1% of maximum rated output
Load RegulationFor 0-100% load variation, with constant nominal line voltage.
Voltage: 0.05% of maximum rated output +2mV
Current: 0.1% of maximum rated output
Voltage Regulation0.05% of maximum rated output +2mV
Transient ResponseTypically recovers in 1.5 ms to within 1% of steady-state output voltage (greater than 50% of Vmax) for 70-100% or 100-70% load change.
Temperature Coefficient0.02%/°C of rated output voltage; 0.03%/°C of rated output current. Change in output per °C change in ambient temperature, with constant line and load.
Efficiency5-8V Models: 82% typical
16-80V Models: 87% typical
150-600V Models: 85% typical (at maximum output power)
Output
3kW ModelsVoltageCurrent
DLM 5-350E0-50-350
DLM 8-350E0-80-350
DLM 16-185E0-160-185
DLM 32-95E0-320-95
DLM 40-75E0-400-75
DLM 60-50E0-600-50
DLM 80-37E0-800-37
DLM 150-20E0-1500-20
DLM 300-10E0-3000-10
DLM 600-5E0-6000-5
4kW ModelsVoltageCurrent
DLM 5-450E0-50-450
DLM 8-450E0-80-450
DLM 16-250E0-160-250
DLM 22-180E *0-220-180
DLM 32-125E0-320-125
DLM 40-100E0-400-100
DLM 60-66E0-600-66
DLM 80-50E0-800-50
DLM 150-26E0-1500-26
DLM 300-13E0-3000-13
DLM 600-6.6E0-6000-6.6
* 22V Model available as 4kW
Output : Voltage and Current
ModelOutput Rating
Voltage (VDC)Current (ADC)
DLM 5-350E0-50-350
DLM 5-450E0-50-450
DLM 8-350E0-80-350
DLM 8-450E0-80-450
DLM 16-185E0-160-185
DLM 16-250E0-160-25
DLM 22-180E *0-220-180
DLM 32-95E0-320-95
DLM 32-125E0-320-125
DLM 40-75E0-400-75
DLM 40-100E0-400-100
DLM 60-50E0-600-50
DLM 60-66E0-600-66
DLM 80-37E0-800-37
DLM 80-50E0-800-50
DLM 150-20E0-1500-20
DLM 150-26E0-1500-26
DLM 300-10E0-3000-10
DLM 300-13E0-300

0-13


DLM 600-5E0-6000-5
DLM 600-6.6E0-6000-6.6
* 22V Model available as 4kW
Output
ModelRegulation Line and Load
Voltage (0.05% of Vmax + 2mV)Current (0.1% of Imax)
DLM 5-350E5 mV350 mA
DLM 5-450E5 mV450 mA
DLM 8-350E6 mV350 mA
DLM 8-450E6 mV450 mA
DLM 16-185E10 mV185 mA
DLM 22-180E *13 mV180 mA
DLM 16-250E10 mV250 mA
DLM 32-95E18 mV95 mA
DLM 32-125E18 mV125 mA
DLM 40-75E22 mV75 mA
DLM 40-100E22 mV100 mA
DLM 60-50E32 mV50 mA
DLM 60-66E32 mV66 mA
DLM 80-37E42 mV37 mA
DLM 80-50E42 mV50 mA
DLM 150-20E77 mV20 mA
DLM 150-26E77 mV26 mA
DLM 300-10E152 mV10 mA
DLM 300-13E152 mV13 mA
DLM 600-5E302 mV55 mA
DLM 600-6.6E302 mV7 mA
* 22V Model available as 4kW
Output
ModelMeter Accuracy
Voltage (0.5% of Vmax + 1 Count)Current (0.75% of Imax + 1 Count)
DLM 5-350E0.04 V4 A
DLM 5-450E0.04 V5 A
DLM 8-350E

0.05 V

4 A
DLM 8-450E0.05 V5 A
DLM 16-185E0.09 V3 A
DLM 16-250E0.09 V3 A
DLM 22-180E *0.2 V3 A
DLM 32-95E0.3 V0.8 A
DLM 32-125E0.3 V1 A
DLM 40-75E0.3 V0.7 A
DLM 40-100E0.3 V0.9 A
DLM 60-50E0.4 V0.5 A
DLM 60-66E0.4 V0.6 A
DLM 80-37E0.5 V0.4 A
DLM 80-50E0.5 V0.5 A
DLM 150-20E0.9 V0.3 A
DLM 150-26E0.9 V0.3 A
DLM 300-10E1.6 V0.09 A
DLM 300-13E1.6 V0.11 A
DLM 600-5E3.1 V0.05 A
DLM 600-6.6E3.1 V0.06 A
* 22V Model available as 4kW
Output
ModelPreview AccuracyOVP Adjustment Range (5% to 110% of Vmax)
Voltage (0.05% of Vmax +1 count)Current ( 1.0% of Imax +1 count)
DLM 5-350E0.04 V5 A0.3-5.5 V
DLM 5-450E0.04 V6 A0.3-5.5 V
DLM 8-350E0.05 V5 A0.4-8.8 V
DLM 8-450E0.05 V6 A0.4-8.8 V
DLM 16-185E0.09 V3 A0.8-17.6 V
DLM 16-250E0.09 V4 A0.8-17.6 V
DLM 22-180E *0.2 V3 A1.1-24.2 V
DLM 32-95E0.3 V1.1 A1.6-35 V
DLM 32-125E0.3 V1.4 A1.6-35 V
DLM 40-75E0.3 V0.9 A2-44 V
DLM 40-100E0.3 V1.1 A2-44 V
DLM 60-50E0.4 V0.6 A3-66 V
DLM 60-66E0.4 V0.8 A3-66 V
DLM 80-37E0.5 V0.5 A4-88 V
DLM 80-50E0.5 V0.6 A4-88 V
DLM 150-20E0.9 V0.3 A7.5-165 V
DLM 150-26E0.9 V0.4 A7.5-165 V
DLM 300-10E1.6 V0.11 A15-330 V
DLM 300-13E1.6 V0.14 A15-330 V
DLM 600-5E3.1 V0.06 A30-660 V
DLM 600-6.6E3.1 V0.08 A30-660 V
Output
ModelRipple and Noise
Ripple (RMS)*Noise (P-P)
DLM 5-350E12 mV100 mV
DLM 5-450E12 mV100 mV
DLM 8-350E12 mV100 mV
DLM 8-450E12 mV100 mV
DLM 16-185E10 mV100 mV
DLM 16-250E10 mV100 mV
DLM 22-180E10 mV100 mV
DLM 32-95E10 mV100 mV
DLM 32-125E10 mV100 mV
DLM 40-75E10 mV100 mV
DLM 40-100E10 mV100 mV
DLM 60-50E15 mV100 mV
DLM 60-66E15 mV100 mV
DLM 80-37E15 mV120 mV
DLM 80-50E15 mV120 mV
DLM 150-20E30 mV200 mV
DLM 150-26E30 mV200 mV
DLM 300-10E60 mV300 mV
DLM 300-13E60 mV300 mV
DLM 600-5E100 mV500 mV
DLM 600-6.6E100 mV500 mV
J3 Connector
1Remote Output Enable14Remote Shutdown Input (+). Positive or negative true logic selection with S1
2Remote Shutdown Return (-)15+5 VDC Auxiliary Output
3Remote OVP Programming Input161 mA Current Source for OVP Programming
4Remote Programming Indicator17OVP Status Indicator
5Operating Mode Indicator18Overtemperature Shutdown Indicator
6Status Indicator Return (-)19DC Voltage Monitor Output
7Current Monitor Output20Remote /Local Voltage Control Select
8Not Used211 mA Current Source for Voltage Programming
9Voltage Programming Input221 mA Current Source for Current Programming
10Current Programming Input23Remote/Local Current Control Select
11Not Used24Not Used
12Programming/Monitor Return (-)25Not Used
13Not Used